Most multilayer jobs meet copper somewhere: at the boiler, the cylinder, a radiator valve or an existing run. We stock three press adaptors that make the change with no heat, plus radiator elbows for the final connection to a radiator valve. Here's how they compare and how to fit them.

At a glance

Copper press adaptor (M-profile) Compression adaptor Copper tail adaptor
Multilayer end Press (U, B, TH or H jaw) Press (U, B, TH or H jaw) Press (U, B, TH or H jaw)
Copper end M-profile press socket for copper pipe Compression nut and olive for copper pipe Plain tail, the same size as copper pipe
Sizes (MLCP x copper) 16x15, 20x15, 20x22 and 25x22mm 16x15, 20x15, 20x22, 25x22, 25x28 and 32x28mm 16x15, 20x15, 20x22, 25x22, 25x28 and 32x28mm
You'll need A U jaw and an M jaw A U jaw and two spanners A U jaw, and a compression fitting or valve for the tail
Best for All-press installations Joints you may need to undo, or where you can't press the copper Going straight into a compression valve or fitting

Copper press adaptor: press both ends

Press one end onto the multilayer pipe and the other onto the copper. There are no spanners and no heat, and both joints are permanent. The ZLX-4064-A press tool takes U-profile jaws and M-profile jaws (15 to 28mm), so one tool does both ends.

  1. Make the multilayer joint first (see "Preparing the multilayer pipe" below) and press it with the U jaw for the pipe size.
  2. Cut the copper square and remove any burrs, inside and out.
  3. Push the copper into the adaptor up to the stop, and mark the pipe at the face of the fitting so you can see it hasn't moved.
  4. Press the copper end with the M jaw for the copper size: M15 or M22.

Shop copper press adaptors

Compression adaptor: press one end, tighten the other

The multilayer end is pressed, and the copper end is a compression joint. Use it where you can't get a press tool onto the copper, or for a joint you may want to undo later, for example next to an appliance.

  1. Press the multilayer end with the U jaw.
  2. Cut the copper square, remove any burrs and wipe the end clean.
  3. Slide on the nut and then the olive, push the copper fully into the adaptor and do the nut up by hand.
  4. Tighten with a spanner while holding the adaptor's body steady with another. Don't overtighten.

Shop compression adaptors

Copper tail adaptor: straight into a valve

This adaptor ends in a plain tail the same size as copper pipe, so it can go straight into a compression fitting or valve, such as an isolating valve or a radiator valve, with no short length of copper in between. Press the multilayer end with the U jaw, then make the compression joint onto the tail as you would onto copper.

Shop copper tail adaptors

Radiators: radiator elbows

For radiators fed from the floor or the wall, our MLCP radiator elbows have a 16mm press end and a leg of 15mm pipe that connects to the radiator valve: 150mm or 300mm in chrome, or 300mm in copper. Cut the leg to length as needed.

Shop radiator elbows

Preparing the multilayer pipe

  1. Cut the pipe square, at 90°.
  2. Bevel the cut end, for example with our MLCP Calibration & Bevelling Set, and check there are no burrs.
  3. Push the pipe into the fitting until you can see it in all three sight holes.
  4. Press with the jaw for the pipe size. Our MLCP fittings work with U, B, TH and H jaws.

The fittings have a flared inlet, so the pipe goes in without calibrating. And if a joint is ever left unpressed, it leaks visibly when you pressure-test, so it can't be missed. Our multilayer pipe guide covers cutting, bending and fitting the pipe in more detail.

Good practice

  • No heat near the fittings: don't solder onto or right next to an MLCP fitting, because heat damages the O-rings and the plastic ring. If there's soldering to do on the copper, do it first, well away from the adaptor, and let it cool.
  • Support the pipe: clip surface-mounted multilayer pipe no more than 1m apart for 16mm, 1.25m for 20mm, 1.5m for 25mm and 2m for 32mm.
  • Check the bonding: copper press joints keep electrical continuity, but multilayer pipe doesn't conduct. If you replace part of a copper run that's used for electrical bonding, make sure the bonding is still in place, or have an electrician add a bond.
  • Mind the weather: install between −10°C and 45°C. Below freezing, keep the pipe and fittings somewhere warmer until you use them.
  • Test: pressure-test the finished system, for example with our Pressure Test Pump.